Meridian Life Science Academic Site

ISOLATE II RNA Mini Kit

Highly efficient purification of total RNA by combining the stringency of guanidinium thiocyanate lysis with the speed and purity of silica-membrane column purification.

ISOLATE II RNA Mini Kit

Fast – simple extraction of high purity total RNA from six samples, ideal for use in all applications, in as little as 30 minutes

High-performance – recovery of consistently high quality RNA from a wide variety of animal, bacterial and plant cells and tissues and cell-free samples

Efficient – optimized lysis conditions and column matrix for recovery of up to 200 µg of high purity RNA from each sample

Convenient – includes all necessary components, including filters (shredders) and DNase I

Safe - no hazardous phenol/chloroform extraction, CsCl centrifugation, LiCl or alcohol precipitation

High quality RNA

RNA was isolated from HeLa cells using ISOLATE II RNA Mini Kit and analyzed by the Bioanalyzer 2100 (Agilent Technologies). The results illustrate A) The quality of RNA, which was found to be exceptional (RIN: ≥9.2) and B) highly reproducible across samples.

Superior performance in real-time applications

RNA was isolated in a 10-fold serial dilution (14,000, 1,400, 140, 14 and 1.4 cells), from mouse 3T3 cells (lanes 1-5 respectively), using ISOLATE II RNA Mini Kit (red traces) and an equivalent kit from Supplier Q (green traces). Subsequently, real-time reverse transcriptase reactions were performed using SensiFAST SYBR No-ROX One-Step Kit. The results illustrate the higher quality of the extraction process over several orders of magnitude, down to a few cells.

Product Description

The ISOLATE II RNA Mini Kit provides a simple, efficient column-based method for the isolation of total RNA from a wide variety of starting materials, without the need for hazardous reagents such as phenol.

By combining the stringency of guanidinium-thiocyanate lysis with the speed and ease-of-use of silica-membrane purification, the ISOLATE II RNA Mini Kit provides a fast method for the purification of high-quality total RNA from animal and plant cells and tissues as well as cultured cells, bacterial cells, yeast, biological fluids and cell-free samples.

Biological samples which are sometimes difficult to process i.e. mouse tissue (liver, brain), various tumor cell lines, Streptococcus and Actinobacillus pleuropneumoniae, will yield high-quality RNA with the ISOLATE II RNA Mini Kit.

The online product manual has protocols for purifying total RNA from cultured cells, tissues, yeast, bacteria, biological liquids, paraffin embedded tissue and RNAlater® treated samples. There is also a protocol for a convenient on-column DNase treatment, using RNase-free DNase I that is supplied with the kit, for applications that are sensitive to very small amounts of DNA.

The ISOLATE II RNA Plant Kit has been designed to deliver optimal performance in RT-qPCR in conjunction with either the SensiFAST cDNA Synthesis Kit and SensiFAST Real-Time PCR Kits, or the SensiFAST One-Step Real-Time RT-PCR Kits. Additionally, the ISOLATE II RNA Plant Kit can be used to purify samples prior to RT-PCR amplification using the Tetro cDNA Synthesis Kit and any enzyme from the Meridian PCR portfolio, including MyTaq DNA Polymerase.

Applications

  • RT-qPCR
  • End-point RT-PCR
  • Northern, dot and slot blotting
  • Array analysis
  • Poly A+ RNA selection
  • RNA-Seq

Product Specification

Reagent 10 Preps 50 Preps 250 Preps
ISOLATE II Filters 10 50 250
ISOLATE II RNA Mini Columns & Collection Tubes 10 50 250
Collection Tubes (2 mL) 30 150 750
Collection Tubes (1.5 mL) 10 50 250
Lysis Buffer RLY 10 mL 25 mL 125mL
Wash Buffer RW1 15 mL 15 mL 80 mL
Wash Buffer RW2 6 mL 12 mL 3 x 25 mL
Membrane Desalting Buffer MEM 10 mL 25 mL 125 mL
Reaction Buffer for DNase I RDN 7 mL 7 mL 30 mL
DNase, RNase-free (lyophilized) 1 Vial 1 Vial
Appearance Colorless
Application RT-qPCR, End-point RT-PCR, Northern, dot and slot blotting, Array analysis, Poly A+ RNA selection, RNA-Seq
Sample type Cultured human or mammalian cells, Human or mammalian tissue
Preparation time Approximately 30 minutes for 6 preps
RNA size distribution > 200 nucleotides
Elution volume 40 – 120 µL
Yield Up to 200 µg of RNA
Storage Store lyophilized DNase I at 4°C and reconstituted at -20°C.

All other kit components at room temperature (18-25°C)

Product Ordering

Cat. No.              Size

BIO-52071          10 Preps

BIO-52072          50 preps

BIO-52073         250 Preps

Product Support Material

View all Documents

I used the ISOLATE II RNA mini kit to isolate RNA from a range of murine ...

Cavan Bennett, Walter and Eliza Hall Institue of Medical Research, Melbourne, Australia

We have been using Meridian products (especially the Isolate II RNA mini Kit, ...

Kuan Won, Mater Research Institute, Brisbane, Australia

I recently used the ISOLATE II RNA Mini kit. I had some cultured cells which ...

Sharon Pok, Australian National University Medical School, Garran, Australia

We have been utilizing ISOLATE II RNA Mini Kit from Meridian and have found ...

Aparna Jayachandran, GMRF-UQ, Brisbane, Australia

FAQs:

ISOLATE II RNA Mini Kit

Can I use columns or solutions from one kit in another one?
The columns supplied with the ISOLATE II kits may appear similar, but each type has been optimized to work within the buffer system supplied with the corresponding kit. The swapping of columns (or buffers) between kits may lead to no recovery of nucleic acid whatsoever, or at the very least severely impaired purification.
Is it possible to interrupt the DNA or RNA extraction protocols?
Interruption of the DNA/RNA extraction process is possible after the sample lysis only. It is possible to homogenize and lyse the samples and to store them in the freezer until use for RNA extraction. RNA clean up with a column cannot be interrupted and we recommend to avoid delays during the column purification process. If a delay is unavoidable the columns should be stored on ice.
Our extracted samples are showing a high 230nm reading, resulting in a bad 260/230 ratio. What is the reason for that and what does it mean in respect to RNA quality?
An increase of A230 values may be caused by different substances, like carbohydrates, peptides and phenol. A bad A230/A260 ratio in RNA samples is mostly due to a contamination with guanidinium thiocyanate which is present in several reagents used for RNA extraction, for instance in the lysis buffer. In contrast to a bad A280/A260 ratio it does not automatically reflect a bad RNA quality. Currently there is no consensus about a lower limit of this ratio and mostly a carry-over of guanidinium thiocyanate does not affect the reliability of downstream applications. Nevertheless, an extra washing step with RW2 would be helpful to avoid this problem. And it would be helpful to pipet the flow-through out of the collection tube, instead of pouring it off.
Which is the recommended kit for processing of soil samples or hard to lyse bacteria?
It is possible to use the ISOLATE II Plant DNA and RNA kits. The optimized lysis of these kits may be also useful for processing difficult to lyse bacteria and fungi in soil samples
What do I need to consider for the clean-up of large fragments?
For the optimal recovery of large RNA/DNA fragments it is necessary to optimize the elution step. To increase the recovery rate it would be helpful to use a larger volume for elution, incubate the column with the elution buffer prior to centrifugation and use repeated elution steps. To avoid excessive dilution it may be helpful to reapply the eluted fraction again.
What is the recommended kit or protocol for RNA extraction from tissues with high lipid content like adipose or brain tissue?
Several possibilities exist. If you are using our column based extraction kit like the ISOLATE II RNA Mini kit it would be necessary to decrease the sample amount of such samples or to increase the amount of the lysis buffer RLY to prevent clogging of the columns. Another possibility would be a pre-extraction with TRIsure (BIO-38032) and to clean up the RNA containing aqueous phase with the column based ISOLATE II RNA kits. You should follow the TRIsure protocol up to the phase separation step. Then mix the aqueous phase with a volume of ethanol and load it onto the column. From there you should proceed with the regular ISOLATE II RNA Mini kit protocol.
I want to process samples treated with RNAlater, what do I have to consider?
These samples are treated as usual, just remove the RNAlater solution.
Can I use a gel to check the quality of RNA samples isolated using the ISOLATE II RNA kits?
Agarose gel analysis of RNA samples can be both valuable and misleading. The pattern of bands on the gel can not only be indicative of the quality of the sample, but equally it can also only indicate that the gel tank, buffer or agarose is contaminated with RNase. A safer measure is to use a Bioanalyzer and look at the RIN value (RNA Integrity Number), which should be as close to 10 as possible, indicating that the RNA is not degraded. A spectrophotometer (ideally a microfluidic one) can also be used to determine the ratio of A260 to A280 for purity determination. All these methods give an idea of the quality of total RNA which tends to be dominated with rRNA and tRNA. It is not uncommon for an agarose gel to show an abundance of 18S and 23S rRNA but on analysis for there to be little of the transcript of interest. Ideally RNA quality control should include an assessment of the presence of common transcripts (from reference genes, such as GAPDH) using RT-PCR or RT-qPCR. If the yield of RNA is low, it is best to first check that all the solutions used and the equipment employed is largely free of RNase. Solutions should be prepared with the highest quality reagents available, preferably ones that have a certificate of analysis to show that they are free of DNase and RNase. If there is confidence that RNase contamination is at a minimum, then it may be worth ensuring that the sample is properly homogenised before lysis and to check a sample of the lysed material under a light microscope to ensure that all the cells are disrupted. RNA samples that have been contaminated with RNase (either during processing or those that have been sent from another lab) can be purified using the ISOLATE II RNA Micro Kit.

Get In Touch With A Specialist

Have questions about a product? Want to learn more about Meridian’s molecular or immunoassay reagent portfolio? We want to hear from you!

By submitting your information in this form, you agree that your personal information may be stored and processed in any country where we have facilities or service providers, and by using our “Contact Us” page you agree to the transfer of information to countries outside of your country of residence, including to the United States, which may provide for different data protection rules than in your country. The information you submit will be governed by our Privacy Statement.